An assembling type thermocouple normally has temperature sensor, fixing parts and junction box. It can work together with temperature transducer, display and thermoregulator to compose an automatic controller of temperature. Its working range is from 0ºC to 1800ºC. | ![]() |
Type |
Code |
Graduation |
Working Range (ºC) |
Deviation Permit |
Ni-Cr—Cu-Ni |
WRK |
E |
0-800 |
±1.5ºC or ±0.25%|t| |
Ni-Cr—Ni-Si |
WRN |
K |
0-1300 |
±1.5ºC or ±0.25%|t| |
Pt10Rh—Pt |
WRP |
S |
0-1600 |
±2.5ºC or ±0.75%|t| |
Pt30Rh—Pt6Rh |
WRR |
B |
0-1800 |
±2.5ºC or ±0.75%|t| |
Thermal Inertia Level |
Time Constant(Sec) |
Thermal Inertia Level |
Time Constant(Sec) |
¢ñ |
90-180 |
¢ó |
10-30 |
¢ò |
30-90 |
¢ô |
≤10 |
|