This series of cable is produced according to BS5308 standard and applicable for computer network control system and other anti-interference connection between detection devices and meters. Working Condition: 1. Rated voltage (U0/U): 300/500V 2. Long-term working temperature: PVC insulated cables - 2 tiers, 70ºC and 105ºC; XPE (PE-Xb and irradiated XPE) insulated cables - 90ºC 3. Fixed installed in environment temperature range -40ºC∼50ºC. 4. Installation temperature: No less than 0ºC. 5. Minimal bending radius: Copper belt shielded cable - 10×external Φ; Armoured cable - 12×external Φ; Other cable - 6×external Φ; |
![]() |
Type and Structure
Type | Structure | ||
Copper conductor PVC insulated PVC sheathed | Copper conductor PE insulated PVC sheathed | Copper conductor XPE insulated PVC sheathed | |
DJVPV | DJYPV | DJYJPV | Braid pair shielded (copper wire or tinning copper wire) |
DJVP2V | DJYP2V | DJYJP2V | Copper belt pair shielded |
DJVP3V | DJYP3V | DJYJP3V | Aluminum-plastic belt pair shielded |
DJVVP | DJYVP | DJYJVP | Braid whole shielded (copper wire or tinning copper wire) |
DJVVP2 | DJYVP2 | DJYJVP2 | Copper belt whole shielded |
DJVVP3 | DJYVP3 | DJYJVP3 | Aluminum-plastic belt whole shielded |
DJVPVP | DJYPVP | DJYJPVP | Braid pair shielded and whole shielded (copper wire or tinning copper wire) |
DJVP2VP2 | DJYP2VP2 | DJYJP2VP2 | Copper belt pair shielded and whole shielded |
DJVP3VP3 | DJYP3VP3 | DJYJP3VP3 | Aluminum-plastic belt pair shielded and whole shielded |
DJVP2V22 | DJYP2V22 | DJYJP2V22 | Copper belt pair shielded & armoured |
DJVP3V22 | DJYP3V22 | DJYJP3V22 | Aluminum-plastic belt pair shielded & armoured |
DJVVP2-22 | DJYVP2-22 | DJYJVP2-22 | Copper belt whole shielded & armoured |
DJVVP3-22 | DJYVP3-22 | DJYJVP3-22 | Aluminum-plastic belt whole shielded & armoured |
DJVP2VP2-22 | DJYP2VP2-22 | DJYJP2VP2-22 | Copper belt pair shielded and whole shielded & armoured |
DJVP3VP3-22 | DJYP3VP3-22 | DJYJP3VP3-22 | Aluminum-plastic belt pair shielded and whole shielded & armoured |
DJVPVR | DJYPVR | DJYJPVR | Braid pair shield, soft structure |
DJVP2VR | DJYP2VR | DJYJP2VR | Copper belt pair shielded, soft structure |
DJVPVPR | DJYPVPR | DJYJPVPR | Braid pair shielded and whole shielded, soft structure |
DJVP2VP2R | DJYP2VP2R | DJYJP2VP2R | Copper belt pair shielded and whole shielded, soft structure |
Type | Voltage Level (U0/U, V) | Number of Wire Cross Setional Area |
NH-VV, NH-VV22, NH-YJV, NH-YJV22 |
600/1000 | 1-4, 3+2 2.5-240(mm2) |
NH-KVV, NH-KYJV, NH-KVV22, NH-KYJV22 |
450/750 | 2-61 2.5-10(mm2) |
NH-BV NH-BVV |
450/750 | 1-5 1.5-240(mm2) |
|